SATEC RPT091 ASCII ÇÁ·ÎÅäÄÝÀÇ Àбâ/¾²±â Á¾·ùº° ÀúÀå³»¿ë°ú Ãâ·Â¹øÁö

 

SATEC RPT091 µå¶óÀ̺êÀÇ Åë½Å ÇÁ·ÎÅäÄÝÀ» ASCII·Î ¼±ÅÃ( PROT ´ÜÀÚ¸¦ Open )ÇßÀ» ¶§ÀÇ Àбâ/¾²±â Á¾·ùº° ¸Þ¸ð¸®¿¡ ÀúÀåµÈ ³»¿ë°ú ÀúÀåÀ§Ä¡´Â ´ÙÀ½°ú °°´Ù.

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ ³»   ¿ë ´Ü À§ ¹ü À§
ÀúÀåÀ§Ä¡ + 0 ~ 2 L1~L3/L12 ~ L31 Àü¾Ð V/KV 0 ~ Vmax
ÀúÀåÀ§Ä¡ + 3 ~ 5 L1 ~ L3 Àü·ù A 0 ~ Imax
ÀúÀåÀ§Ä¡ + 6 ~ 8 L1 ~ L3 Àü·Â(KW) KW/MW -Pmax ~ Pmax
ÀúÀåÀ§Ä¡ + 9 ~ 11 L1 ~ L3 Power Factor - -0.99 ~ 1
ÀúÀåÀ§Ä¡ +12 KW Total KW/MW -Pmax ~ Pmax
ÀúÀåÀ§Ä¡ +13 Power Factor Total - -0.99 ~ 1
ÀúÀåÀ§Ä¡ +14 KWh Import KWh/MWh 0 ~ 99999
ÀúÀåÀ§Ä¡ +15 Neutral (Unbalanced) Àü·ù A 0 ~ Imax
ÀúÀåÀ§Ä¡ +16 ÁÖÆļö HZ 45 ~ 65
ÀúÀåÀ§Ä¡ + 17 ~ 19 L1 ~ L3 Kvar Kvar/Mvar -Pmax ~ Pmax
ÀúÀåÀ§Ä¡ + 20 ~ 22 L1 ~ L3 KVA KVA/MVA -Pmax ~ Pmax
ÀúÀåÀ§Ä¡ + 23 Kvarh net Kvarh/Mvarh -9999.9 ~ 99999
ÀúÀåÀ§Ä¡ + 24 Kvar total Kvar/Mvar -Pmax ~ Pmax
ÀúÀåÀ§Ä¡ + 25 KVA total KVA/MVA 0 ~ Pmax
ÀúÀåÀ§Ä¡ +26 Sliding window maximum KW demand KW/MW 0 ~ Pmax
ÀúÀåÀ§Ä¡ +27 Accumulated KW demand
ÀúÀåÀ§Ä¡ + 28 ~ 30 L1 ~ L3 Max. amp. demand A 0 ~ Imax
ÀúÀåÀ§Ä¡ + 31 Status inputs   »óÅ °ª
ÀúÀåÀ§Ä¡ + 32 KWh Export KWh/MWh 0 ~ -9999
ÀúÀåÀ§Ä¡ +33 Sliding window maximum KVA demand KVA/MVA 0 ~ Pmax
ÀúÀåÀ§Ä¡ + 34 ~ 36 L1~L3/L12 ~ L31 THD Àü¾Ð % 0 ~ 999.9
ÀúÀåÀ§Ä¡ + 37 ~ 39 L1~L3 THD Àü·ù
ÀúÀåÀ§Ä¡ + 40 KVAh KVAh/MVAh 0 ~ 99999999
ÀúÀåÀ§Ä¡ + 41 Sliding window KW demand KW/MW -Pmax ~ Pmax
ÀúÀåÀ§Ä¡ + 42 Sliding window KVA demand KVA/MVA
ÀúÀåÀ§Ä¡ + 43 Reserved (»ç¿ë¾ÈÇÔ) - -
ÀúÀåÀ§Ä¡ +44 ~ 46 L1 ~ L3 TDD Àü·ù % 0 ~ 99.9

<Ç¥ 1> DATA ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ °¡´É)

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±â
Address
³»     ¿ë ´Ü À§

¹ü À§

ÀúÀåÀ§Ä¡ + 0 0 Wiring mode -

0 ~ 6,

(0 = 3OP2,

1 = 4LN3,

2 = 3DIR2,

3 = 4LL3,

4 = 3OP3,

5 = 3LN3,

6 = 3LL3)

1 PT Ratio

1.0 ~ 6500.0

2 CT Primary Àü·ù A

1 ~ 50000

3 Demand °£°Ý min

1, 2, 5, 10, 15, 20, 30, 60,

255 = ¿ÜºÎ Sync

4 Demand periods No -

1 ~ 15

5 Ampere Demand °£°Ý sec

0 ~ 1800

6 Æò±Õ ¹öÆÛ Å©±â -

8, 16, 32

7 Reset Enable/Disable

0 = Disable,

1 = Enable

8 ±âº» ÁÖÆļö HZ

50, 60

9 ÃÖ´ë Demand Load Àü·ù A

1 ~ 50000

10 Phase Energy Mode -

 0 = Disable,

1 = Enable

<Ç¥ 2> SETUP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (1 °³ÀÇ Setup Data¸¸ Àбâ/¾²±â °¡´É)

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡

³»     ¿ë

ºñÆ®º° »óÅÂ

ÀúÀåÀ§Ä¡ + 0

Relay »óÅÂ

0 ~ 5  Bit : Ç×»ó 1,

6      Bit : Relay 2 »óÅÂ,

7      Bit : Relay 1 »óÅÂ,

8 ~ 15 Bit : Ç×»ó 0,

 

* Relay »óÅÂ

0 = Operated,

1 = Released

<Ç¥ 3> STATUS ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ °¡´É)

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡

³»     ¿ë

¹ü À§

ÀúÀåÀ§Ä¡ + 0

Firmware version ¹øÈ£

0 ~ 65535

<Ç¥ 4> VER ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ °¡´É)

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡

Àбâ Address

³»     ¿ë

¹ü À§

ÀúÀåÀ§Ä¡ + 0

AO Àбâ = 0 ~ 15,

ACH Àбâ = 0 ~ 13

AO, ACH Àбâ Register ¹øÈ£

AO : 0 ~ 15,

ACH : 0 ~ 13

ÀúÀåÀ§Ä¡ + 2

AO, ACH allocation register parameter ID

0 ~ 1611h

( <Ç¥ 6> ÂüÁ¶ )

ÀúÀåÀ§Ä¡ + 3

AO, ACH zero scale (0/4 mA)

<Ç¥ 6> ÂüÁ¶

ÀúÀåÀ§Ä¡ + 4

AO ACH full scale (20/1 mA)

<Ç¥ 5> AO, ACH ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ Áö¿ø)

 

 

ID ¹øÈ£(16Áø¼ö)

ID ¹øÈ£(10Áø¼ö)

³»     ¿ë

¹ü À§

´Ü À§

0h

0

¾øÀ½

0

-

C00h ~ C03h

3072 ~ 3074

L1/L12 ~ L3/L31 Àü¾Ð ÇöÀç °ª

0 ~ Vmax

V

C03h ~ C05h

3075 ~ 3077

L1 ~ L3 Àü·ù ÇöÀç °ª

0 ~ Imax

A

F00h

3840

Total KW ÇöÀç °ª

-Pmax ~ Pmax

KW

F01h

3841

Total Kvar ÇöÀç °ª

Kvar

F02h

3842

Total KVA ÇöÀç °ª

0 ~ Pmax

KVA

F03h

3843

Total PF ÇöÀç °ª

-1 ~ 1

-

F04h

3844

Total PF lag ÇöÀç °ª

0 ~ 1

F05h

3845

Total PF lead ÇöÀç °ª

1002h

4098

ÁÖÆļö

0 ~ 100.0

HZ

1100h ~ 1102h

4352 ~ 5354

L1/L12 ~ L3/L31 Æò±Õ Àü¾Ð

0 ~ Vmax

V

1103h ~ 1105h

4355 ~ 4357

L1 ~ L3 Æò±Õ Àü·ù

0 ~ Imax

A

1400h

5120

Total KW Æò±Õ °ª

-Pmax ~ Pmax

KW

1401h

5121

Total Kvar Æò±Õ °ª

Kvar

1402h

5122

Total KVA Æò±Õ °ª

0 ~ Pmax

KVA

1403h

5123

Total PF Æò±Õ °ª

-1 ~ 1

-

1404h

5124

Total PF lag Æò±Õ °ª

0 ~ 1

1405h

5125

Total PF lead Æò±Õ °ª

1501h

5377

Neutral Æò±Õ Àü·ù

0 ~ Imax

A

1502h

5378

Æò±Õ ÁÖÆļö

0 ~ 100.0

HZ

160Fh

5647

Accumulated KW demand

0 ~ Pmax

KW

1611h

5649

Accumulated KVA demand

KVA

<Ç¥ 6> Analog Output Parameter ID ¹øÈ£ ¹× ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±â Address

³»     ¿ë

Bit º° ³»¿ë

ÀúÀåÀ§Ä¡ + 0 0

Status Input allocation

0 ~ 3 bit = DI 1 ~ 4 allocation status,

(0 : not allocated, 1 : allocated to the group)

 

4 ~ 15 bit = »ç¿ë¾ÈÇÔ ( 0 )

1

Pulse Input allocation

2

AO multiplexer allocation

3

External synchronization allocation

<Ç¥ 7> DI Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡,
Ãâ·Â¹øÁö
³»     ¿ë

¹ü À§

Register ID No

(Á÷Á¢ address 16Áø¼ö)

ÀúÀåÀ§Ä¡ + 0 ~ 1 1¹ø, 2¹ø Relay Control »óÅÂ

0 = Normal Operation,

1 = Force Operate,

2 = Force Release.

 8400h (1¹ø ¸±·¹ÀÌ),

8401h (2¹ø ¸±·¹ÀÌ)

<Ç¥ 8> RELAY Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡

³»     ¿ë

¹ü À§

ÀúÀåÀ§Ä¡ + 0

Pulsing relay ID

0 ~ 1 = 1 ~ 2¹ø relay ¹øÈ£

ÀúÀåÀ§Ä¡ + 1

ÁöÁ¤ÇÑ RelayÀÇ Pulsing setpoint Parameter ID

0 ~ 7

(0 = none,

1 = KWh import,

2 = KWh export,

4 = Kvarh import(inductive),

5 = Kvarh export(capacitive),

6 = Kvarh total,

7 = KVA total)

ÀúÀåÀ§Ä¡ + 2

ÁöÁ¤ÇÑ RelayÀÇ Pulsing setpoint ´ÜÀ§½Ã°£ ´ç Pulse ¼ö

Energy pulsing  = 1 ~ 9999

±âŸ = 0.

<Ç¥ 9> PULSE ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àбâ)

 

 

Ãâ·Â ÀÎÀÚ

³»     ¿ë

¹ü À§

Station

RPT091 ÀÇ ID ¹øÈ£

1 ~ 247

Address

Pulsing setpoint relay ¹øÈ£

0 ¶Ç´Â 1   (1  ~ 2¹ø relay ¹øÈ£)

Extra1

PULSE

°íÁ¤   ( PULSE ¾²±â ¸í·ÉÁöÁ¤ )

Extra2

Pulsing setpoint Parameter ID

0 ~ 7  ( <Ç¥ 9> ÂüÁ¶ )

Ãâ·Â °ª

-

Energy pulsing  = 1 ~ 9999

±âŸ = 0.

<Ç¥ 10> PULSE ¾²±âÀÇ Ãâ·ÂÀÎÀÚ

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡

³»     ¿ë

¹ü À§

ÀúÀåÀ§Ä¡ + 0

ÇöÀç½Ã°£ Sec (ÃÊ)

0 ~ 59

ÀúÀåÀ§Ä¡ + 1

ÇöÀç½Ã°£ Min (ºÐ)

0 ~ 59

ÀúÀåÀ§Ä¡ + 2

ÇöÀç½Ã°£ Hour (½Ã)

0 ~ 23

ÀúÀåÀ§Ä¡ + 3

ÇöÀ糯¥  Day (ÀÏ)

1 ~ 31

ÀúÀåÀ§Ä¡ + 4

ÇöÀ糯¥  Month (¿ù)

1 ~ 12

ÀúÀåÀ§Ä¡ + 5

ÇöÀ糯¥  Year (³â)

0 ~ 99

ÀúÀåÀ§Ä¡ + 6

ÇöÀ糯¥ Week (¿äÀÏ)

1 ~ 7 (1 = Sunday, ¡¦)

<Ç¥ 11> RTC Àбâ Á¾·ùÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

*) RTC ¾²±â ¸í·ÉÀº ÇöÀç½Ã°£À» Power Meter¿¡ Àü¼ÛÇÑ´Ù.

Ãâ·ÂÀÎÀÚ´Â Extra1¿¡ RTC ¸¸À» ÀÔ·ÂÇÏ°í ³ª¸ÓÁö ÀÎÀÚ´Â ºóÄ­(¶Ç´Â 0)À¸·Î ¼³Á¤ÇÑ´Ù.

 

 

Àбâ¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Ãâ·Â¹øÁö

³»     ¿ë

¹ü À§ (16Áø¼ö)

Register ID No

(Á÷Á¢ address 16Áø¼ö)

ÀúÀåÀ§Ä¡ + 0 ~ 119 0 ~ 119

User-Define

Register 0 ~ 119

0h ~ FFFFh

(Register ID No)

8100h ~ 8177h

<Ç¥ 12> DEFINE Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

Àбâ¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Ãâ·Â¹øÁö

³»     ¿ë

¹ü À§

Register ID No

(Á÷Á¢ address 16Áø¼ö)

ÀúÀåÀ§Ä¡ + 0 ~ 119 0 ~ 119

User-Definable

Data 0 ~ 119

Mapping µÈ(<Ç¥ 12>) Register¿¡ µû¶ó ¡¦

8000h ~ 8077h

<Ç¥ 13> MAP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

*) MAP ¾²±â´Â DEFINE µÈ Register ID ¹øÈ£°¡ ¾²±â °¡´ÉÇÑ ¿µ¿ªÀÏ ¶§¸¸ Ãâ·ÂÇÒ ¼ö ÀÖ´Ù.

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±â Address ³»     ¿ë

¹ü À§

Register ID No
(Á÷Á¢ address 16Áø¼ö)
ÀúÀåÀ§Ä¡ + 0 0 1¹ø Alarm setpoint Trigger Parameter ID

0 ~ 9405h

(<Ç¥ 15> ÂüÁ¶)

8200h
ÀúÀåÀ§Ä¡ + 1 1 1¹ø Alarm setpoint Action

0 = No Action,

12288 = Operate Relay 1,

12289 = Operate Relay 2

8201h
ÀúÀåÀ§Ä¡ + 2 ~ 3 2 ~ 3 1¹ø Alarm setpoint Operate, Release Delay

0 ~ 9999 (x 0.1 ÃÊ)

8202h ~ 8203h
ÀúÀåÀ§Ä¡ + 4 ~ 5 4 ~ 5 1¹ø Alarm setpoint Operate, Release limit

Parameter ID ¿¡ µû¶ó¡¦

(<Ç¥ 15> ÂüÁ¶)

8204h ~ 8205h
ÀúÀåÀ§Ä¡ + 6 ~ 11 6 ~ 11 2¹ø Alarm setpoint ID, Action, Delay, Limit

1¹ø Alarm Setpoint ¿Í
µ¿ÀÏ

8206h ~ 820Bh
ÀúÀåÀ§Ä¡ + 12 ~ 89 12 ~ 89 3 ~15¹ø Alarm setpoint ID, Action, Delay, Limit 820Ch ~ 8259h
ÀúÀåÀ§Ä¡ + 90 ~ 95 90 ~ 95 16¹ø Alarm setpoint ID, Action, Delay, Limit 825Ah ~ 825Fh

<Ç¥ 14> ALARM Àбâ,¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

Alarm Trigger Parameter ID(16 Áø¼ö) Alarm Trigger Parameter ID(10Áø¼ö)

³»     ¿ë

¹ü À§ ´Ü À§
0 0

»ç¿ë¾ÈÇÔ

- -
600h ~ 603h 1536 ~ 1539

Status Input 1 ~ 4 ON

8600h ~ 8603h 34304 ~ 34307

Status Input 1 ~ 4 OFF

8901h 35073

Positive phase rotation Reversal

8902h 35074

Negative phase rotation Reversal

C03h ~ C05h 3075 ~ 3077

High Àü·ù L1 ~ L3

0 ~ Imax A
8C03h ~ 8C05h 35843 ~ 35845

Low Àü·ù L1 ~ L3

E00h 3584

High Àü¾Ð ÇöÀç °ª

0 ~ Vmax V
8D00h 36096

Low Àü¾Ð ÇöÀç °ª

E07h ~ E08h 3591 ~ 3592

High Àü¾Ð/Àü·ù THD

0 ~ 999.9 %
E0Ah 3594

High  Àü·ù TDD

0 ~ 100.0
1002h 4098

High ÁÖÆļö

0 ~ 100.0 HZ
9002h 36866

Low ÁÖÆļö

1103h ~ 1105h 4355 ~ 4357

High Àü·ù L1 ~ L3 Æò±Õ °ª

0 ~ Imax A
9103h ~ 9105h 37123 ~ 37125

Low Àü·ù L1 ~ L3 Æò±Õ °ª

1300h 4864

High Àü¾Ð Æò±Õ °ª

0 ~ Vmax V
9200h 37376

Low Àü¾Ð Æò±Õ °ª

1406h ~ 1407h 5126 ~ 5127

High total KW import, export

0~ Pmax KW
1408h ~ 1409h 5128 ~ 5129

High total Kvar import, export

Kvar
1402h 5122

High total KVA

KVA
9404h ~ 9405h 37892 ~ 37893

Low total PF lag, lead

0 ~ 1.000 -
1501h 5377

High Neutral Àü·ù

0 ~ Imax A
1603h ~ 1605h 5635 ~ 5637

High ampere demand L1 ~ L3

1606h 5638

High block KW demand

0 ~ Pmax KW
1608h 5640

High block KVA demand

KVA
1609h 5641

High sliding window KW demand

KW
160Bh 5643

High sliding window KVA demand

KVA
160Fh 5647

High accumulated KW demand

KW
1611h 5649

High accumulated KVA demand

KVA

<Ç¥ 15> ALARM Àбâ, ¾²±â ¸í·ÉÀÇ Trigger Parameter ID¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±â Address ³»     ¿ë

¹ü À§

Register ID No
(Á÷Á¢ address 16Áø¼ö)
¾²±â
ÀúÀåÀ§Ä¡ + 0 0 Reserved

Ç×»ó 65535

8500h -
ÀúÀåÀ§Ä¡ + 1 1 Interface

1 = RS422,

2 = RS485

8501h °¡´É
ÀúÀåÀ§Ä¡ + 2 2 Address

0 ~ 247

8502h
ÀúÀåÀ§Ä¡ + 3 3 Baud rate

0 = 110,

1 = 300,

2 = 600,

3 = 1200,

4 = 2400,

5 = 4800,

6 = 9600,

7 = 19200

8503h
ÀúÀåÀ§Ä¡ + 4 4 Data format

0 = 7 data bits/even parity,

1 = 8 data bits/no parity,

2 = 8 data bits/even parity

8504h

<Ç¥ 16> COMM Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ ³»     ¿ë

¹ü À§

Register ID No
(Á÷Á¢ address 16Áø¼ö)
ÀúÀåÀ§Ä¡ + 0 Relay status

0 ~ 1bit = 1 ~ 2¹ø Relay status,

    (OFF : released, ON : Operate)

2bit ~ 15 bit = »ç¿ë¾ÈÇÔ.( Ç×»ó 0 )

7D00h
ÀúÀåÀ§Ä¡ + 1 Reserved

Ç×»ó 0

7D01h
ÀúÀåÀ§Ä¡ + 2 Status inputs

0 ~ 3bit = 1 ~ 4¹ø Status input,

    (OFF : Open, ON : Closed)

4bit ~ 15 bit = »ç¿ë¾ÈÇÔ.( Ç×»ó 0 )

7D02h
ÀúÀåÀ§Ä¡ + 3 Setpoints status

0 ~ 15bit = 1 ~ 16¹ø Setpoints status,

(OFF : released, ON : Operate)

7D03h

<Ç¥ 17> ESR ÀбâÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë (Àб⸸ °¡´É)

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±â Address

³»     ¿ë

¹ü À§

Register ID No

(Á÷Á¢ address 16Áø¼ö)

ÀúÀåÀ§Ä¡ + 0 0

Setpoints alarm status

0 ~ 15bit = 1 ~ 16¹ø Setpoints alarm status

(OFF : released, ON : Operate)

7E00h

ÀúÀåÀ§Ä¡ + 1 1

Self-check alarm status

0 bit = Reserved,

1 bit = ROM error,

2 bit = RAM error,

3 bit = Watchdog timer reset,

4 bit = Sampling failure,

5 bit = Out of control trap,

6 bit = Reserved,

7 bit = Timing failure,

8 bit = Loss of power (power up),

9 bit = External reset (warm restart),

10bit = Configuration corrupted,

11bit = RTC time synchronization required,

12 ~ 15 bit = reserved

(OFF : released, ON : Operate)

7E01h

<Ç¥ 18> ASR Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

¸Þ¸ð¸® ÀúÀåÀ§Ä¡ Àбâ/¾²±â Address ³»     ¿ë

¹ü À§

Register ID No

(Á÷Á¢ address 16Áø¼ö)

ÀúÀåÀ§Ä¡ + 0 0 Instrument Option 1

0  Bit : 120V Option,

1  Bit : 690V Option,

2 ~ 4  Bit : Reserved,

5  Bit : 50% Àü·ù over range option,

6  Bit : Analog Output 0/4 ~ 20mA Option,

7  Bit : Analog Output 0 ~ 1mA Option,

8  Bit : Analog Output -1 ~ +1mA Option,

9  Bit : Relays Option,

10 Bit : Digital Inputs Option,

11 ~ 15 Bit : Reserved

7F00h

ÀúÀåÀ§Ä¡ + 1 1 Instrument Option 2

0 ~ 2 Bit : Number of Relays - 1,

3 ~ 6 Bit : Number of Digital Inputs - 1,

7 ~ 15  Bit : Reserved,

7F01h

<Ç¥ 19> OPTION Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë

 

 

* DIRECT – Long Size Direct Àбâ/¾²±â, VARIABLE – Variable Size Direct Àбâ/¾²±â´Â À§ÀÇ <Ç¥ 1> ~ <Ç¥ 19> Register ID No (Á÷Á¢ address = 16Áø¼ö ¹øÁö) ¹øÁö¸¦ ÀÔ·ÂÇÏ¿© Àбâ/¾²±â¸¦ ¼öÇàÇÑ´Ù.

 

DIRECT ÀÐÀ» Á¾·ùÀÇ Àбâ´Â Ç×»ó 4 BYTE (8 BYTE ASCII µ¥ÀÌÅÍ ) µ¥ÀÌÅ͸¦ Åë½Å ÇÁ·Î±×·¥(PLC_SCAN.EXE) ¸Þ¸ð¸®¿¡ º¸°üÇÏ°í VARIABLE Àбâ´Â ÀÐÀº ¸ðµç µ¥ÀÌÅ͸¦ 1BYTE ´ÜÀ§·Î Åë½Å ÇÁ·Î±×·¥(PLC_SCAN.EXE)ÀÇ ¸Þ¸ð¸®¿¡ º¸°üÇÑ´Ù.

¶ÇÇÑ ¾²±â´Â Ãâ·Â Á¾·ù¿¡ µû¶ó 1 BYTE( 2 BYTE ASCII µ¥ÀÌÅÍ ), 2 BYTE( 4 BYTE ASCII µ¥ÀÌÅÍ ), 4 BYTE( 8 BYTE ASCII µ¥ÀÌÅÍ ) µ¥ÀÌÅ͸¦ Power Meter¿¡ Àü¼ÛÇÑ´Ù.